==Europe==
 
==Europe==
   −
European countries use a 230V, 50Hz standard for domestic power. The power cable entering a domestic property typicially passes first through a tamper-evident high-current fuse. This serves both as a last-resort isloator, and a means to disconnect power from the consumer unit for maintinance. An earth or ground line comes in along with the power cables in most modern installations - older houses may take this from a water pipe, but this is being phased out. Following the fuse, both live and neutral cables connect to a tamper-evident power meter for billing purposes. The output of this meter is typicially legally defined as the legal demarkation point between utility company and propertyholder ownership and responsibility.
+
European countries use a 230V, 50Hz standard for domestic power. The power cable entering a domestic property typically passes first through a tamper-evident high-current fuse. This serves both as a last-resort isolator, and a means to disconnect power from the consumer unit for maintenance. An earth or ground line comes in along with the power cables in most modern installations - older houses may take this from a water pipe, but this is being phased out. Following the fuse, both live and neutral cables connect to a tamper-evident power meter for billing purposes. The output of this meter is typically legally defined as the legal demarcation point between utility company and property holder ownership and responsibility.
   −
Typicially, the next component will be an isolation switch, allowing the property owner to disconnect power without breaking the tamper-evident seal on the company fuse. Often, this isolator is an RCB which automaticially isolates in the event of a fault. It may be a physically seperate box, or a component within a consumer unit.
+
Typically, the next component will be an isolation switch, allowing the property owner to disconnect power without breaking the tamper-evident seal on the company fuse. Often, this isolator is an RCB which automatically isolates in the event of a fault. It may be a physically separate box, or a component within a consumer unit.
   −
The design of the consumer unit is similar to that of a US distribution system, with common terminal blocks for all neutral and ground wires and a single live rail which connects to all breakers. Depending on age and property size, either fuses or a consumer unit containing breakers may be used. This distributes power to each individual circuit. The number and classes of circuits can vary greatly, and typicially include lighting and ring-mains. Newly connected outbuildings should be given their own circuit.
+
The design of the consumer unit is similar to that of a US distribution system, with common terminal blocks for all neutral and ground wires and a single live rail which connects to all breakers. Depending on age and property size, either fuses or a consumer unit containing breakers may be used. This distributes power to each individual circuit. The number and classes of circuits can vary greatly, and typically include lighting and ring-mains. Newly connected outbuildings should be given their own circuit.
    