Changes

Jump to navigation Jump to search
Line 15: Line 15:  
| RAID 3 || All but one drive use RAID 0. The last drive is dedicated to storing a parity bit from each sequential bit across all stripes. ||  
 
| RAID 3 || All but one drive use RAID 0. The last drive is dedicated to storing a parity bit from each sequential bit across all stripes. ||  
 
|-
 
|-
−
| '''RAID 5''' || Uses one drives-worth of space out of the array (striped across all drives) to store a parity bit from each sequential bit across all stripes.  When any one drive fails, the contents of that lost drive can be slowly calculated out using the remaining drives and the parity data. || This only offers single-drive redundancy, so if a second drive fails (something not uncommon during a restoration, due to the increased load) all data may be lost.
+
|RAID 4|| ||
 
|-
 
|-
−
|RAID 4|| ||
+
| '''RAID 5''' || Uses one drives-worth of space out of the array (striped across all drives) to store a parity bit from each sequential bit across all stripes.  When any one drive fails, the contents of that lost drive can be slowly calculated out using the remaining drives and the parity data. || This only offers single-drive redundancy, so if a second drive fails (something not uncommon during a restoration, due to the increased load) all data may be lost. With increasing hard drive sizes, this is increasingly a problem which is driving many people to RAID 6.
 
|-
 
|-
 
| '''RAID 6''' || Uses two drives-worth of space out of the array (striped across all drives) to store parity data from each sequential bit across all stripes.  When one or two drives fail, the contents of that lost drive(S) can be slowly calculated out using the remaining drives and the parity data. || This cost more storage space than RAID 5, but offers added protection against a second failure during the restoration process.
 
| '''RAID 6''' || Uses two drives-worth of space out of the array (striped across all drives) to store parity data from each sequential bit across all stripes.  When one or two drives fail, the contents of that lost drive(S) can be slowly calculated out using the remaining drives and the parity data. || This cost more storage space than RAID 5, but offers added protection against a second failure during the restoration process.
Block, Siteadmin, SkipCaptcha, Upload, Automoderated users, Check users, delete, edit, Moderators, move, oversight, protect, ratelimit-exempt, rollback, Administrators
20,635

edits

Navigation menu