'''RAID''' (Redundant Array of Inexpensive Disks or Drives, or Redundant Array of ''Independent'' Disks) is a class of data storage architecture intended to reduce the risk of data loss.  Since storage media will inevitably fail eventually for one reason or another, RAID attempts to provide redundancy for active data which will enable users to survive drive failures with all of their data intact. The exception to this in RAID 0, which provides no redundancy, but improves added functionality as long as their are no failures.
 
'''RAID''' (Redundant Array of Inexpensive Disks or Drives, or Redundant Array of ''Independent'' Disks) is a class of data storage architecture intended to reduce the risk of data loss.  Since storage media will inevitably fail eventually for one reason or another, RAID attempts to provide redundancy for active data which will enable users to survive drive failures with all of their data intact. The exception to this in RAID 0, which provides no redundancy, but improves added functionality as long as their are no failures.
 +
 +
==Striping==
 +
An integral part of all RAID architectures except for RAID 1 is striping. Striping is the process of breaking data into chunks, and spreading these chunks across multiple drives. So, if a single massive file were to be placed on a striped array, multiple small segments of that file would be deposited on each drive.  When that file is then read in its entirety, all of the drives would go to work simultaneously, loading the needed data chunks from each drive and assembling them.
    
==RAID types==
 
==RAID types==
Line 7: Line 10:  
! RAID type !! Function !! Notes
 
! RAID type !! Function !! Notes
 
|-
 
|-
−
| '''RAID 0''' || Stripes (strings back and forth across all drives) data across all drives in an array, making many physical drives one virtual drive. This offers both convenience and speed, since the drive array looks and acts like one drive, while the read/write load is distributed across multiple drives|| This offers no redundancy, so a single drive failure can destroy much if not all of the data therein.
+
| '''RAID 0''' || Stripes data across all drives in an array, making many physical drives one virtual drive. This offers both convenience and speed, since the drive array looks and acts like one drive, while the read/write load is distributed across multiple drives|| This offers no redundancy, so a single drive failure can destroy much if not all of the data therein.
 
|-
 
|-
 
| '''RAID 1''' || Mirroring: the contents of one drive are copied bit for bit onto another drive.  In case of failure, there is already a complete copy ready to use. || This is the most "expensive" kind of RAID, since half (or more, if non-equivalent drive sizes are used) is lost to redundancy.
 
| '''RAID 1''' || Mirroring: the contents of one drive are copied bit for bit onto another drive.  In case of failure, there is already a complete copy ready to use. || This is the most "expensive" kind of RAID, since half (or more, if non-equivalent drive sizes are used) is lost to redundancy.
Line 15: Line 18:  
| RAID 3 || All but one drive use RAID 0. The last drive is dedicated to storing a parity bit from each sequential bit across all stripes. ||  
 
| RAID 3 || All but one drive use RAID 0. The last drive is dedicated to storing a parity bit from each sequential bit across all stripes. ||  
 
|-
 
|-
−
|RAID 4|| ||
+
|RAID 4 || ||
 
|-
 
|-
 
| '''RAID 5''' || Uses one drives-worth of space out of the array (striped across all drives) to store a parity bit from each sequential bit across all stripes.  When any one drive fails, the contents of that lost drive can be slowly calculated out using the remaining drives and the parity data. || This only offers single-drive redundancy, so if a second drive fails (something not uncommon during a restoration, due to the increased load) all data may be lost. With increasing hard drive sizes, this is increasingly a problem which is driving many people to RAID 6.
 
| '''RAID 5''' || Uses one drives-worth of space out of the array (striped across all drives) to store a parity bit from each sequential bit across all stripes.  When any one drive fails, the contents of that lost drive can be slowly calculated out using the remaining drives and the parity data. || This only offers single-drive redundancy, so if a second drive fails (something not uncommon during a restoration, due to the increased load) all data may be lost. With increasing hard drive sizes, this is increasingly a problem which is driving many people to RAID 6.